    你的位置:首頁 > 技術文章 > 如何測量您的成像系統中的景深

    技術文章

    如何測量您的成像系統中的景深

    技術文章

    Gauging Depth of Field in Your Imaging System

    Over the years, we have answered countless questions regarding lens performance. Of those questions, none have been more difficult to define than requests for depth of field. The reason for this difficulty has more to do with the vagueness of the question than with the inability to provide a measured or calculated value. Consider for a moment what depth of field ls us. It is the distance by which an object may be shifted before an unacceptable blur is produced. For depth of field to be properly stated, it should contain not only the displacement of an image, but also a specific resolution. The depth of field specification is further complicated by a type of keystoning aberration that often occurs. This result can dramatically affect linear measurements and therefore render depth of field unusable. In this article we will take a closer look at depth of field calculations and compare them to physical measurements using the DOF 1-40 depth of field gauge. The gauge, as we will see later, offers a unique look at what depth of field really means and how we as system designers may wish to quantify this parameter. A simple geometric approximation for depth of field is shown in Figure 1.0. The linear blur (required resolution) Bp, Bm and Bf can be expressed in terms of angular blur by the following equation.

    Figure 1

     

    Using similar triangles, a relationship can now be made between angular blur and the focus point,

    where λ is the aperture of the lens. Solving for δplus and δmin,

    The derivation above is very specific to the intended resolution. However, many theoretical derivations of depth of field often assume the lens resolution to be nearly diffraction limited. The most popular of these derivations are based on microscope applications. A typical example for the total depth of field (dplus + dmin) is shown below.

    Where λ is the wavelength and NA equals the numerical aperture of the lens.

    In order to study depth of field we have put together a simple macro system consisting of a 25mm fixed focal length lens, 8mm spacer and Sony XC-75 monochrome CCD video camera. The system was chosen not for its performance but rather for its common real world implementation. Measurements were performed using the DOF 1-40 target. The target allows us to measure depth of field at either 1, 10, 20 or 40 lp/mm over a maximum depth of 50mm. The flat field resolution of this system is approximay 15 lp/mm at 0.3X primary magnification. For purposes of our experiment, a blur spot resolution of 0.1 mm or 10 lp/mm was chosen. Depth of field measurements were taken at three aperture settings corresponding to f/2, f/4, and f/8. An important point should be noted about aperture settings. The f-number shown on most fixed focal length lenses is calculated with the object at infinity. As a result, we have adjusted our NA and therefore our aperture values for a 95mm working distance.

    The values below highlight a number of points to consider. In general our calculated and measured delta d are fairly close. However, the displacement of the image due to defocus aberrations was not predicted by our calculations. This type of displacement error could certainly be problematic if the system contained an auto iris. If we compare our measured results to the delta-theory, we notice a significant variation. As we mentioned earlier, this variation is due to a false assumption concerning system resolution.

    Another property that should be noted in our DOF 1-40 observations is the non-uniform magnification seen through the depth of field range. This is a very common problem in most lenses and, as we stated earlier, can yield significant errors if measurements are made throughout the full depth of field range. Edmund Optics provides several ecentric options to correct for this type of error.

    In the end, it is the total performance of an optical system that counts. As a full service supplier and manufacturer of optics, illumination, CCD cameras, monitors, mounting, and electronic imaging related products, Edmund Optics has the knowledge and resources to look at your application as a total system. In fact, innovative tools such as the DOF 1-40 have come about from our own in-house need to quantify system performance. So if you are looking for individual components that can be integrated into your system or starting from scratch, our engineers are ready to help.

    聯系我們

    地址:江蘇省江陰市人民東路1091號1017室 傳真:0510-68836817 Email:sales@rympo.com
    24小時在線客服,為您服務!

    版權所有 © 2026 江陰韻翔光電技術有限公司 備案號:蘇ICP備16003332號-1 技術支持:化工儀器網 管理登陸 GoogleSitemap

    在線咨詢
    QQ客服
    QQ:17041053
    電話咨詢
    0510-68836815
    關注微信
    主站蜘蛛池模板: 亚洲国产精品一二三区| 柠檬福利第一导航在线| 日韩欧美1区2区3区免费看。| 久操香蕉| 日韩精品国产另类专区| 国产丝袜肉丝视频在线| 口爆人妻| 99精品国产兔费观看久久99| 成人欧美一区二区三区| 91插逼| 一边捏奶头一边高潮视频| 日韩美av一区二区三区| 国语字幕av| 漂亮人妻被黑人久久精品| 合阳县| 国产乱人伦av在线a更新| 欧洲欧美人成免费全部视频| 亚洲高清乱码午夜电影网| 国产精品麻豆欧美日韩ww| 91色色网| 亚洲成a人片在线观看www| 亚洲成人动漫在线观看| 日韩中文网| 欧美丝袜你懂的| 色九月亚洲综合网| 大陆一级毛片免费播放| 久热这里只有精品视频3| 97人妻无码免费专区| 久久中文字幕人妻丝袜系列| 台湾色综合| 色吊丝二区三区中文写幕| 免费A级毛片樱桃视频| 国产成人区在线观看视频| 亚洲国产区| 国产一区二区丝袜在线播放国产日韩欧美色综合 | 国产第9页| 亚洲大成色www永久网站动图| 精品国产av一区二区果冻传媒| 奇骏影院在线观看免费版| 毛片无遮挡高清免费| www.777奇米色|